Modbus TCP Ethernet converter Remote IO Module Data Acquisition 2AO Supports Register Mapping inquiry for VFD control M200T

Modbus TCP Ethernet converter Remote IO Module Data Acquisition 2AO Supports Register Mapping inquiry for VFD control M200T
  • Продавецalatbantusex.us
  • Список ценUS $51.90piece
  • Продажная ценаUS $51.90piece
  • ДоставкаБесплатная доставка
  • Рейтинги4,5 (313)

Oписание продукта

C2000 MDI8 channel isolation enhanced intelligent analog digital acquisition system, 8 Road, 24 bit high precision current mode analog input (range -40mA~40mA), the channel isolation, fully differential input and output interpolation design, ensure that the equipment is suitable for more complex environment. 2 digital (dry contact) input, RS485 interface photoelectric isolation and power isolation technology, effective suppression of lightning, lightning, ESD and co ground interference. And supports user calibration, to meet the accuracy requirements of almost all cases. The standard Modbus RTU protocol has been integrated into the system integrators and engineering companies. The data acquisition and control of remote analog and on / off devices can be realized by RS-485. The equipment usually has a proximity switch and a mechanical switch, button, light sensor, photoelectric switch and LED digital switching equipment and PH, conductivity meter, thermometer, hygrometer, pressure gauge, flow meter, valve starter and analog equipment.
Characteristic:
8 analog input (current);
2 digital dry contact input;
I/O and system isolation;
AI resolution: 24 bit;
AI input channel to take full differential input, support calibration, interpolation output;
Isolation between analog input channels, isolation 350VDC;
AI input measurement range: -40mA~ 40mA;
Modbus RTU communication protocol;
RS485 communication interface provides photoelectric isolation and 600W surge protection per line;
The power supply has the function of over current and over voltage protection and anti reverse connection;
Easy installation.
1.2 technical parameters
Analog interface
AI
8 path differential input
AI resolution
24bit
AI range
-40mA~40mA (calibration)
AI channel isolation
350V DC
AI input impedance
240.
Digital input interface
DI
2 way dry contact input
DI protection
Overpressure is less than 240V, the flow is less than 80mA
Serial communication parameters
Interface type
RS-485
baud rate
1200~115200bps
Data bit
Eight
Parity check
None
Stop bit
One
flow control
None
communication protocol
Modbus RTU
Serial protection
Serial ESD protection
1.5KV
Serial lightning protection
600W
Serial overcurrent
Less than 240V, less than 80mA
Power parameters
Power specifications
9-24VDC (recommended 12VDC)
Electric current
[email protected]
Surge protection
1.5kW
Overvoltage, overcurrent
60V, 500mA
work environment
Operating temperature and humidity
-25~85 DEG C, 5~95%RH, no gel
Storage temperature and humidity
-60~125 DEG C, 5~95%RH, no gel
Other
size
72.1*121.5*33.6mm